TASARIM · IKB-043

Tolerance Stack-Up: Worst-Case or Statistical RSS?

In a five-part assembly, the same tolerances fail worst-case analysis but pass RSS analysis. The difference between the two methods and when to pick each.

5×20 mm ±0.05 mmgap ≈0.30 mmP1P2P3P4P5Housing

In a five-part stack-up assembly, the gap dimension may be derived from individual part tolerances of ±0.05 mm, but the feedback from the assembly line is always the same: in some combinations the gap closes to zero, in others it stays too loose. When you run the tolerance stack-up calculation using the worst-case method, manufacturing engineering asks you to tighten the tolerances; run the same calculation using the statistical (RSS) method and you’ll find the assembly works with high confidence using those exact same tolerances. Both are “correct” calculations, but they rest on different assumptions — and which one you pick directly affects part cost.

In this note I compare the two methods using a simple five-part linear stack-up example and draw a practical line for deciding which one to use and when.

Two philosophies: worst-case and statistical summation#

The worst-case method assumes that every part’s tolerance simultaneously goes to its worst extreme, and in the same direction. It answers the question: if all five parts are produced at the upper limit at once, or all at the lower limit, what happens to the assembly gap? Mathematically it’s a simple summation:

$$ T_{WC} = \sum_{i=1}^{n} T_i $$

This approach is physically guaranteed: every combination produced falls within this range, because the range itself was drawn around the worst-case scenario. The cost is that tolerances grow quickly — as part count increases, the allowable individual tolerance narrows, because the total tolerance budget grows linearly.

The statistical method (root-sum-square, RSS) asks a different question: if parts are produced independently and randomly, and the probability of all of them hitting the worst extreme at once is practically zero, what is the distribution of the total stack-up? The variance of the sum of independent, normally distributed variables equals the sum of the individual variances:

$$ \sigma_{total}^2 = \sum_{i=1}^{n} \sigma_i^2 \quad\Rightarrow\quad T_{RSS}=\sqrt{\sum_{i=1}^{n} T_i^2} $$

When you define the tolerance range as \(\pm3\sigma\) (i.e., \(T_i=3\sigma_i\)), the total tolerance also becomes \(\pm3\sigma_{total}\), and the formula above can be written directly in terms of tolerances.

L1 20±0.05L2 20±0.05L3 20±0.05L4 20±0.05L5 20±0.05ΣL nominal = 100 mmgap (closing dimension)P1P2P3P4P5Housing inner surface
Figure 1 Linear dimension chain of the five-part stack-up: individual tolerances along the top, closing gap dimension on the right.

The cost of the assumptions: when RSS lies to you#

The confidence level that RSS claims (typically \(\pm3\sigma\), about 99.7% under a normal distribution) rests on two assumptions: part dimensions are approximately normally distributed, and the manufacturing processes are statistically independent of one another. Five parts machined on the same machine tool, with the same cutting tool, during the same shift, may not be truly independent — systematic tool wear can shift all of them in the same direction. Also, using RSS without demonstrating the process is actually under control (typical acceptance criterion \(C_{pk}\geq1.33\)) produces a calculation that looks confident on paper but offers no guarantee on the shop floor.

A point often skipped when defending RSS: the formula assumes independent, normally distributed variables. Five parts cut back-to-back on the same CNC machine from the same tool batch are not truly statistically independent; tool wear or thermal drift can shift all of them in the same direction. If such correlation exists, the real stack-up will come out wider than the RSS estimate.

Worked example: gap in a five-part stack-up#

Worked example

Given: 5 plates, each with nominal length \(L=20\,\mathrm{mm}\), machining tolerance \(\pm0.05\,\mathrm{mm}\) (verified with measurement data, \(C_{pk}\geq1.33\)). Housing inner length nominal \(100.30\,\mathrm{mm}\), taken as toleranceless. Functional requirement: assembly gap minimum \(0.10\,\mathrm{mm}\), maximum \(0.50\,\mathrm{mm}\).

Nominal gap: $$ G_{nom} = 100.30 – 5\times20 = 0.30\,\mathrm{mm} $$

Worst-case: $$ T_{WC} = \sum_{i=1}^{5} T_i = 5\times0.05 = 0.25\,\mathrm{mm} $$ Gap range: \(0.30\pm0.25=[0.05;\,0.55]\,\mathrm{mm}\). The lower bound \(0.05\,\mathrm{mm}\) is below the required \(0.10\,\mathrm{mm}\). ✗ not acceptable

RSS: $$ T_{RSS} = \sqrt{\sum_{i=1}^{5} T_i^2} = 0.05\sqrt{5} \approx 0.112\,\mathrm{mm} $$ Gap range: \(0.30\pm0.112=[0.188;\,0.412]\,\mathrm{mm}\), both bounds fall within \([0.10;\,0.50]\). ✓ acceptable (subject to Cpk condition)

Result: with identical tolerances, worst-case rejects the assembly while RSS accepts it — once process capability has been proven. The difference is purely in the assumption.

Which method applies to which situation#

In practice, the decision depends on the criticality of the part and whether you have real process data on hand:

  • If a single failure can cause loss of life or equipment (a structural aircraft fastener, contact gap spacing in a high-voltage breaker) — use worst-case, because it must guarantee the outcome.
  • High-volume serial production with process capability proven by data (\(C_{pk}\geq1.33\)) — use RSS, because it relaxes the tolerance budget and lowers cost.
  • Low volume, prototype, or new supplier — don’t trust RSS; start with worst-case when process data is absent, then relax as data accumulates.
  • When part count exceeds 8-10, worst-case tends to produce practically impossible tolerances; this is where RSS or hybrid semi-statistical methods come into play.
  • In non-adjustable assemblies where the gap is a direct functional safety dimension, use worst-case; for cosmetic or secondary gap criteria, RSS is sufficient.
5×20 mm ±0.05 mm (stack-up)gapP1P2P3P4P5Housing
Figure 2 Exploded isometric view: five parts along the same assembly axis, with the closing gap defined relative to the housing.

Tolerance analysis in software#

SOLIDWORKS’s TolAnalyst add-in computes both worst-case and statistical (RSS) modes on the same dimension chain, and automatically extracts the chain from tolerances defined with DimXpert. In CATIA V5, the Functional Tolerancing & Annotation (FT&A) module performs a similar function and also supports 3D tolerance chains in an assembly context. In Siemens NX, the Variation Analysis module runs on a Monte Carlo basis; it gives more realistic results than RSS when the distribution isn’t normal — for example, with skewed tolerances on cast parts. When the normal-distribution assumption is questionable, or part count is low (the central limit theorem works poorly), a simple Monte Carlo script you build in MATLAB or Minitab — randomly sampling from each part’s measured distribution and building thousands of virtual assemblies — produces a more trustworthy histogram than the RSS formula.

The tolerance you feed into SOLIDWORKS TolAnalyst, CATIA FT&A, or Siemens NX Variation Analysis is the drawing tolerance — not the distribution the process actually produces. The software hands you a nice histogram and a percentage, but if the input \(C_{pk}\) hasn’t been measured, the output is just as much of an assumption. On critical assemblies, the real \(\sigma\) should be verified with at least one pilot-lot measurement.

Key takeaways#

  • Worst-case: \(T=\sum T_i\), guarantees physical fit, narrows tolerances quickly as part count rises.
  • RSS: \(T=\sqrt{\sum T_i^2}\), assumes independence and normal distribution, relaxes the tolerance budget but requires proof of process capability.
  • In the five-part example, the same \(\pm0.05\,\mathrm{mm}\) tolerance is rejected by worst-case, accepted by RSS given \(C_{pk}\geq1.33\).
  • Worst-case for critical/life-safety parts, RSS for proven serial production.
  • Software output is only as reliable as the input tolerance — don’t trust RSS without a measured real \(C_{pk}\).

On the next tolerance chain review, here’s the order I follow: first calculate with worst-case and flag spots where tolerances narrow unreasonably; at those spots, ask whether real process data (measurements, \(C_{pk}\)) exists; if data exists, switch to RSS and clearly document the confidence level; if not, either collect pilot measurements or stick with worst-case. Write down which method you chose in the drawing note — that’s the most valuable piece of information for the engineer who revisits that tolerance three years from now.

Back to top